Electrical Safety

Electrical Safety

Spec 4.4 · Cambridge IGCSE Physics: Revision notes

Studying this course? Keep your progress in one place.

Key facts

  • Damaged insulation and damp conditions cause shocks and fires.
  • Overloading causes heating: P=I2RP = I^2R. Doubling the current gives four times the heat.
  • The switch and fuse go in the live wire; the earth wire gives a safe path to ground.
  • A fuse melts when the current is too high; choose a rating just above the normal current.
  • Appliances are double-insulated or earthed.

Insulation and damp

Damaged insulation exposes live wires, and water conducts current, so both raise the risk of shock and fire.

Cracked insulation lets you touch a live conductor, and can cause short circuits and overheating. Water is a good conductor and lowers body resistance, so bathrooms, kitchens and outdoors are most risky. Link each hazard to its consequence.

Damaged insulation

  • Exposes live conductors: electric shock
  • Short circuits: overheating and fire

Damp conditions

  • Water conducts current through the body
  • Moisture in equipment causes short circuits
  • Wet skin has the lowest resistance

Why is a wet bathroom especially dangerous?

Overheating and overload

Too much current heats the wire, which can melt the insulation near flammable materials.

Heating in a wire follows P=I2RP = I^2R, so doubling the current gives four times the heat. Plugging too many appliances into one extension lead draws a large current through thin wiring.

  • Heating in a wireP=I2RP = I^2R

Worked example: overloaded extension lead

A 3 kW kettle, a 2 kW heater and a 1.5 kW toaster are plugged into one 13 A extension lead on a 230 V supply. Is the lead overloaded?

The current in a cable doubles. The heating becomes...

The mains circuit

The live wire carries the supply voltage, the neutral completes the circuit and the earth is a safety wire.

The switch and fuse must be in the live wire. Then when the switch is open, the appliance is not live and is safe to touch. If a fault connects live to a metal case, a large current flows through the earth wire and blows the fuse.

Live

Colour:
Brown
Voltage:
About 230 V
Role:
Carries current; dangerous

Neutral

Colour:
Blue
Voltage:
About 0 V
Role:
Return path

Earth

Colour:
Yellow/green
Voltage:
0 V
Role:
Safety path to ground
  1. 1

    Fault

    the live wire touches the metal casing

  2. 2

    Large fault current

    flows to ground through the low-resistance earth wire

  3. 3

    Protection device operates

    the fuse melts or the trip switch opens

  4. 4

    Circuit broken

    the casing is no longer live

A fault in an earthed appliance

Which wire should the switch be in?

Fuses and trip switches

A fuse melts when the current is too high; a trip switch (RCD) opens quickly when live and neutral currents are not equal.

A fuse has a thin wire that melts, breaking the circuit; it must be replaced. Its rating should be a little above the normal current but not above the cable rating. A trip switch (RCD) compares current in live and neutral; a difference means current is leaking, so it trips.

Appliance
A fuse in series with the appliance melts and breaks the circuit if the current is too large.

Fuse

Type:
Wire melts
Response:
Slow (about 0.2 s)
Reusable:
Replace after blowing
Detects:
Overcurrent only

Trip switch

Type:
Electromagnetic
Response:
Very fast (about 20 ms)
Reusable:
Reset by flipping
Detects:
Overcurrent and earth leakage

Worked example: choosing a fuse

A 2300 W heater is used on a 230 V supply. Which fuse (3 A, 5 A or 13 A) is suitable?

A 1200 W microwave runs on 230 V (I = 5.2 A). Which fuse?

Double insulation and earthing

Both stop the casing becoming live. Double insulation keeps live parts out of reach; earthing lets fault current escape safely.

Double-insulated appliances (plastic casing, double-square symbol) need no earth wire because the casing cannot conduct. Earthed appliances have a metal casing connected to the earth wire, so a fault sends a large current to ground and blows the fuse.

Double-insulated

  • Plastic casing
  • No earth wire
  • Hairdryers, power drills

Earthed

  • Metal casing joined to earth
  • Earth wire needed
  • Older kettles, toasters, irons

Why does an earthed metal kettle blow its fuse if the live wire touches the case?

Try an exam question

A 2300 W heater is used on a 230 V supply. Calculate the current, and choose a fuse from 3 A, 5 A and 13 A. Give a reason.

[3 marks]

That's the notes covered.

Carry on to the next subtopic.

Try a question

An old toaster's mains cable has become frayed, exposing the bare copper wire beneath the plastic insulation. What hazard does this damaged insulation create?

1 mark, marked against the mark scheme

Revision notes