- What is background radiation?
- Ionising radiation present in the environment at all times, from sources like radon gas, rocks/buildings, food/drink and cosmic rays.
- Name the four main sources of background radiation.
- Radon gas in the air; rocks and buildings; food and drink; cosmic rays.
- How is ionising radiation typically measured?
- Using a detector connected to a counter, giving a count rate in counts per second or per minute.
- How do you calculate the corrected count rate?
- Measured count rate minus the background count rate.
- Why must background radiation be subtracted before calculating half-life?
- Because the raw count rate always includes background radiation, which would give an incorrect half-life if not removed.
- Define half-life.
- The time taken for half the nuclei of a particular isotope in a sample to decay.
- How else can half-life be described in terms of count rate?
- The time taken for the (corrected) count rate or activity of a sample to fall to half its original value.
- Does half-life depend on the amount of sample present?
- No — half-life is a fixed property of the isotope, independent of sample size.
- How would you find the half-life from a decay curve?
- Find the starting corrected count rate, then read off the time taken for it to fall to half that value.
- Why is an alpha source with a long half-life used in household smoke alarms?
- Alpha radiation ionises air effectively in the small detection chamber, and a long half-life means the source does not need frequent replacement.
- Why is gamma radiation used to sterilise medical equipment?
- Because gamma radiation penetrates deeply enough to reach through packaging and kill microorganisms.
- Why should a medical treatment isotope have a short half-life?
- To limit the patient's exposure to radiation after the treatment is complete.
- Why does a thickness-gauging source need a long half-life?
- So that its radiation output stays roughly constant over the period it is used to monitor thickness.
- What two factors must be considered when choosing an isotope for a specific use?
- The type of radiation emitted (for penetrating power) and its half-life (for how long the source needs to remain useful).
- If a corrected count rate starts at 800 counts/minute and the half-life is 10 minutes, what is the count rate after 20 minutes?
- 200 counts/minute (800 to 400 after one half-life, then 200 after two half-lives).