Half-Life

Half-Life Flashcards

Spec 5.2.4 · Cambridge IGCSE Physics: Flashcards

Studying this course? Keep your progress in one place.

Flip each card. Be honest: the ones you mark Not yet come back first.

15 cards

Tap a card to flip it. Swipe right if you knew it, left if not.

See all 15 cards
What is background radiation?
Ionising radiation present in the environment at all times, from sources like radon gas, rocks/buildings, food/drink and cosmic rays.
Name the four main sources of background radiation.
Radon gas in the air; rocks and buildings; food and drink; cosmic rays.
How is ionising radiation typically measured?
Using a detector connected to a counter, giving a count rate in counts per second or per minute.
How do you calculate the corrected count rate?
Measured count rate minus the background count rate.
Why must background radiation be subtracted before calculating half-life?
Because the raw count rate always includes background radiation, which would give an incorrect half-life if not removed.
Define half-life.
The time taken for half the nuclei of a particular isotope in a sample to decay.
How else can half-life be described in terms of count rate?
The time taken for the (corrected) count rate or activity of a sample to fall to half its original value.
Does half-life depend on the amount of sample present?
No — half-life is a fixed property of the isotope, independent of sample size.
How would you find the half-life from a decay curve?
Find the starting corrected count rate, then read off the time taken for it to fall to half that value.
Why is an alpha source with a long half-life used in household smoke alarms?
Alpha radiation ionises air effectively in the small detection chamber, and a long half-life means the source does not need frequent replacement.
Why is gamma radiation used to sterilise medical equipment?
Because gamma radiation penetrates deeply enough to reach through packaging and kill microorganisms.
Why should a medical treatment isotope have a short half-life?
To limit the patient's exposure to radiation after the treatment is complete.
Why does a thickness-gauging source need a long half-life?
So that its radiation output stays roughly constant over the period it is used to monitor thickness.
What two factors must be considered when choosing an isotope for a specific use?
The type of radiation emitted (for penetrating power) and its half-life (for how long the source needs to remain useful).
If a corrected count rate starts at 800 counts/minute and the half-life is 10 minutes, what is the count rate after 20 minutes?
200 counts/minute (800 to 400 after one half-life, then 200 after two half-lives).

Flashcards