Transformers Flashcards
Studying this course? Keep your progress in one place.

Flip each card. Be honest: the ones you mark Not yet come back first.
15 cards
Tap a card to flip it. Swipe right if you knew it, left if not.
See all 15 cards
- What are the three main structural components of a transformer?
- A transformer consists of: (1) primary coil – the input coil connected to the AC supply, (2) secondary coil – the output coil that delivers the transformed voltage, and (3) iron core – a soft iron core that links the two coils and carries the changing magnetic field.
- Explain how a transformer works using electromagnetic induction.
- An alternating current in the primary coil creates a changing magnetic field in the iron core. This changing magnetic field passes through the secondary coil, inducing an alternating voltage in it. The magnitude of the induced voltage depends on the ratio of turns in the two coils.
- State the transformer turns ratio equation.
- V₁/V₂ = n₁/n₂, where V₁ is the primary voltage, V₂ is the secondary voltage, n₁ is the number of turns in the primary coil, and n₂ is the number of turns in the secondary coil.
- What is the power equation for an ideal transformer?
- V₁I₁ = V₂I₂, where V₁ and I₁ are the primary voltage and current respectively, and V₂ and I₂ are the secondary voltage and current respectively. This shows that power is conserved in an ideal transformer.
- Define a step-up transformer.
- A step-up transformer is a transformer where the secondary coil has more turns than the primary coil (n₂ > n₁). It increases the voltage and decreases the current.
- Define a step-down transformer.
- A step-down transformer is a transformer where the secondary coil has fewer turns than the primary coil (n₂ < n₁). It decreases the voltage and increases the current.
- If a step-up transformer has a turns ratio of 1:10, and the primary voltage is 230 V, what is the secondary voltage?
- Using V₁/V₂ = n₁/n₂: 230/V₂ = 1/10, therefore V₂ = 230 × 10 = 2300 V.
- A transformer has a primary current of 10 A at 230 V. If the secondary voltage is 2300 V, what is the secondary current?
- Using V₁I₁ = V₂I₂: (230)(10) = (2300)(I₂), therefore 2300 = 2300I₂, so I₂ = 1 A.
- Why are transformers essential in the National Grid?
- Transformers are used in the National Grid to step up voltage for transmission (reducing current and therefore energy losses) and to step down voltage for safe use in homes and businesses. This makes power transmission efficient over long distances.
- Explain why stepping up voltage reduces energy losses in transmission.
- Power loss in transmission cables is given by I²R. When voltage is stepped up, current decreases proportionally (since power is conserved). Since energy loss depends on the square of the current, reducing current significantly reduces energy wasted as heat in the cables.
- What type of current is required for a transformer to work?
- Transformers only work with alternating current (AC). A direct current (DC) does not produce a changing magnetic field, so no voltage will be induced in the secondary coil.
- In the National Grid, why is a step-up transformer used at power stations?
- Step-up transformers increase the voltage to very high levels (e.g. 400 kV) for transmission across the country. This reduces the current and minimises energy losses as heat in the transmission cables.
- In the National Grid, why is a step-down transformer used before electricity reaches homes?
- Step-down transformers reduce the high transmission voltage (e.g. 400 kV) to lower, safer voltages (230 V in the UK) suitable for domestic use in homes and businesses.
- What is an ideal transformer?
- An ideal transformer is a transformer with 100% efficiency, where all magnetic flux from the primary coil links with the secondary coil and there are no energy losses. In reality, transformers have losses due to resistance in the coils and incomplete flux linkage.
- If a transformer has 500 turns in the primary coil and 100 turns in the secondary coil, is it a step-up or step-down transformer?
- It is a step-down transformer because the secondary coil has fewer turns than the primary coil (100 < 500). The secondary voltage will be lower than the primary voltage.