Standard electrode potentials and the hydrogen electrode
Studying this course? Keep your progress in one place.
Key facts
- Oxidation is loss of electrons (oxidation number rises); reduction is gain (oxidation number falls).
- E° is measured against the SHE at 298 K, 100 kPa and 1.00 mol dm⁻³.
- The standard hydrogen electrode has platinum, at 100 kPa and 1.00 mol dm⁻³ , and E° = 0.00 V by definition.
- Only a potential difference can be measured, so a reference electrode is needed.
- Use an inert platinum electrode for non-metals and for two ions of the same element.
- A high-resistance voltmeter and a salt bridge complete the measurement.
Redox and oxidation numbers
Oxidation is loss of electrons and a rise in oxidation number; reduction is gain and a fall.
Oxidation is loss of electrons (oxidation number increases); reduction is gain (oxidation number decreases): OIL RIG.
Rules: uncombined elements 0; compounds sum to 0, ions to their charge; H +1; O −2 (−1 in peroxides); F −1.
Examples: (s-block), (p-block), (d-block).
An oxidising agent is reduced; a reducing agent is oxidised. The oxidation number is the charge if all bonds were ionic.
- Oxidationloss of electrons, oxidation number up
- Reductiongain of electrons, oxidation number down
Worked example
In , which species is oxidised and which is reduced?
- 1
Cr in : 2x + 7(−2) = −2, so x = +6 each.
- 2
Cr in Cr³⁺ is +3: it falls, so it is reduced.
- 3
Fe rises from +2 to +3: it is oxidised.
What is the oxidation number of nitrogen in ?
What E° means
E° is the emf of a half-cell connected to the standard hydrogen electrode under standard conditions.
A half-cell links two forms of a species by an equilibrium, written as a reduction: .
The standard electrode potential, E°, is the emf when the half-cell is connected to a standard hydrogen electrode under standard conditions: 298 K, gases at 100 kPa, ions at 1.00 mol dm⁻³.
More positive E°: the left-hand species is a stronger oxidising agent. More negative E°: the right-hand species is a stronger reducing agent.
- Standard conditions298 K, 100 kPa, 1.00 mol dm⁻³
A half-cell has a very negative E°. What does this tell you?
The standard hydrogen electrode
Only a potential difference can be measured, so the SHE, defined as 0.00 V, is the reference.
The potential of one half-cell cannot be measured alone, so a reference electrode is used. The standard hydrogen electrode (SHE) is the half-cell , assigned E° = 0.00 V.
Platinum is inert and conducts electrons. Platinum black has a large surface area that adsorbs hydrogen, so equilibrium is set up quickly.
- 1
Gas
Hydrogen at 100 kPa bubbled over the electrode
- 2
Solution
1.00 mol dm⁻³ , such as hydrochloric acid
- 3
Temperature
298 K
- 4
Electrode
Platinum coated with platinum black
Why is a platinum electrode used in the SHE?
Measuring E° for each half-cell type
Join the half-cell to the SHE with a salt bridge and read a high-resistance voltmeter; use platinum when no metal is present.
A salt bridge (filter paper soaked in potassium nitrate) joins the half-cells. A high-resistance voltmeter draws almost no current, so concentrations stay constant. Its reading is E°; the sign shows the polarity.
Where there is no metal to act as the electrode, use inert platinum.
- 1
Set up both half-cells
the test half-cell and the SHE, at standard conditions
- 2
Platinum if needed
use an inert platinum electrode where there is no metal
- 3
Salt bridge
filter paper soaked in potassium nitrate joins the half-cells
- 4
High-resistance voltmeter
draws almost no current, so the reading is E°
| Metal and its ion | Non-metal and its ion | Two ions of one element | |
|---|---|---|---|
| Example | Cu²⁺ | Cu | Cl₂ | Cl⁻ | Fe³⁺ | Fe²⁺ |
| Electrode | The metal itself | Platinum | Platinum |
| Solution or gas | 1.00 mol dm⁻³ of its ions | 1.00 mol dm⁻³ Cl⁻ with Cl₂ at 100 kPa bubbled over it | Both ions at 1.00 mol dm⁻³ |
Metal and its ion
- Example:
- Cu²⁺ | Cu
- Electrode:
- The metal itself
- Solution or gas:
- 1.00 mol dm⁻³ of its ions
Non-metal and its ion
- Example:
- Cl₂ | Cl⁻
- Electrode:
- Platinum
- Solution or gas:
- 1.00 mol dm⁻³ Cl⁻ with Cl₂ at 100 kPa bubbled over it
Two ions of one element
- Example:
- Fe³⁺ | Fe²⁺
- Electrode:
- Platinum
- Solution or gas:
- Both ions at 1.00 mol dm⁻³
Which electrode is used for the Fe³⁺ | Fe²⁺ half-cell?
Core Practical 12
Build cells from metals in 1.00 mol dm⁻³ solutions of their ions and compare the voltages with E° data.
Build cells from half-cells of metals in 1.00 mol dm⁻³ solutions of their ions and measure the cell voltage. Compare readings with values calculated from E° data.
Small differences arise from non-standard conditions, impure or oxidised surfaces, and the voltmeter drawing some current. Clean strips with emery paper.
- 1
Clean the metals
Rub each strip with emery paper to remove the oxide layer
- 2
Prepare solutions
Fresh solutions of known concentration at about 298 K
- 3
Join the half-cells
Salt bridge of filter paper soaked in potassium nitrate; fresh strip for each pair
- 4
Measure
Read the high-resistance voltmeter and record the polarity
- 5
Compare
With values calculated from E° data
Why is the metal strip cleaned with emery paper?
Try an exam question
Describe how you would measure the standard electrode potential of the Fe³⁺ | Fe²⁺ half-cell. Give the details of the reference electrode and the conditions.
[5 marks]
- [1]Connect the Fe³⁺ | Fe²⁺ half-cell to a standard hydrogen electrode.
- [1]Fe half-cell: platinum electrode in a solution containing Fe³⁺ and Fe²⁺, each at 1.00 mol dm⁻³.
- [1]Hydrogen electrode: platinum black electrode, H2 at 100 kPa, 1.00 mol dm⁻³ H⁺.
- [1]Join with a salt bridge (filter paper soaked in potassium nitrate solution), at 298 K.
- [1]Read a high-resistance voltmeter connected across the electrodes: the reading is E°.
That's the notes covered.
Carry on to the next subtopic.
Try a question
What is the oxidation number of chromium in the dichromate(VI) ion, Cr₂O₇²⁻?
1 mark, marked against the mark scheme
What is the oxidation number of chromium in the dichromate(VI) ion, Cr₂O₇²⁻?
1 mark, marked against the mark scheme